Home
>
Company Info
>
Windows Hosting
>
Linux Hosting
>
Reseller Hosting
>
Dedicated Servers 24hr Live Help!
WebHostingSriLanka®
Domain Registration
Shared Hosting
Reseller Plans
Cpanel Reseller Plans
Dedicated Servers
VPS Servers
Contact Us
Company Info
.
.
30 Days Money Back!
.
99.99% Uptime!
.
 
 
.
24hr Sales Support!
"
Customer Testimonials  
 
Going with Web Hosting Srilanka was one of the best choices we've made. whenever a problem does occur they fix it quickly and professionally.

Meesha Gunawardana
www.meeshaphotography.com

.
I wanted to say thanks for all of your hard work getting our site up and running quickly. I can honestly say that their plans, service and support have far exceeded our expectation.
 
Craig wotson
www.megamaxdirectory.com
"
 
 
.We gladly accept...
Discover Visa Master Card Amex
 
.
 
.
Unlimited Reseller & Shared Hosting
  WebHostingSrilanka | Webhosting Overview | Data Center Call Now!
We maintains one most redundant datacenters in the United States.
 
Web Hosting Srilanka Data Center Features Such Accommodations.
 
Our Atlanta USA Data Center Facility.
Datacenter Network Connection Overview
All our equipment is located in a centralized, fault tolerant, redundant, climate controlled cage that connects directly to the heart of the Internet via multiple fiber optic connections - no middle tiers. All servers will also have direct access to RouteSciences PathControl to ensure the fastest routes possible for
all your visitors. Anyone who needs fast, uncongested routing will appreciate the fact that PathControl
Free Consultation
Need help creatin the best solution for your business?
Call +94-777-777-776
Press 1
OR
Start a Live Chat with
a WHS Sales Rep.
 
Live Help!
  optimizes Layer 3 routing, making all IP-based applications including Web Email VoIP, FTP, and others predictable and highly available. Gaming servers and audio/video streaming servers will see the biggest advantage of RouteScience PathControl.
  WebHostingSrilanka Main Network Backbones:
 
MCI Global Network
MCI Global Network
MCI's global IP network is one of the highest quality, most scalable, and rigorously engineered Internet networks in the world, spanning six continents. MCI has over 4,500 company-owned global points of presence (POPs) making it the most expansive IP network in the world.
Level(3) Communications
Level(3) Communications
Level(3) operates the world's first international network optimized end-to-end for IP packet switching technology, allowing much more information to be transmitted at a far lower cost. The Level(3) network includes local loops in 36 cities in the U.S. and Europe.
UUNet Data Carrier
UUNet Data Carrier
UUNet has developed and deployed a highly advanced Tier-1 global network to provide their customers the world's best IP services. Designed exclusively for IP data transport, the network spans the globe to move Internet traffic at the highest possible speeds.Built to ensure network reliability and maximum performance, the UUNet Global IP Network provides your business with the absolute best backbone available.
WilTel Communications
WilTel Communications
WilTel has an OC-192 IP backbone with OC-12 uplinks in our markets and data centers; that means we have one of the highest capacity and scalable IP backbones in the industry, along with the highest levels of performance and reliability. A suite of world-class tools that facilitate the communication of customer information and continuous network monitoring set the WilTel network apart from its rivals.
TimeWarner Telecom Inc
TimeWarner Telecom Inc
TimeWarner is one of the few national Tier 1 IP backbone providers in the U.S. Their MPLS-enabled IP packet over SONET (PoS) backbone - engineered and operated by leading IP experts - offers superior redundancy, lower costs and unsurpassed IP reliability.
   
  > Datacenter/Network Overview:
 
WHS has chosen Level3 Communications as its Data Center. The state-of-the-art data center features everything that you would expect from any high-end Colocation facility, plus a lot more. We take pride in our track record of providing the most reliable Internet services available anywhere. Since we moved into our new $10 million dollar data center, we have had 100% uptime (excluding prescheduled maintenance and upgrades during our normal service window). With speed and reliability as our primary design concerns, we have found a network that meets those specifications.
  .
 
> Power: Redundant 4000 AMP, 480-volt electrical feeds, power our data center. This system provides automatic switching between two independent transformers located on theproperty.
Besides a total of One Megawatt of redundant UPS power, our facility houses a fully redundant 2,400 AMP, -48V, positive ground DC Telco power plant and distributionsystem. This system currently powers all fiber providers as well as carriers in our facility.A fully redundant One Megawatt paralyzing UPS system, redundant Master and Emergency System Busses (MSB/ESB) and a 2 Megawatt Diesel Generator system with 3500 gallons of fuel, provides backup power for the facility.
 
  A fully redundant One Megawatt paralyzing UPS system, redundant Master and Emergency System Busses (MSB/ESB) and a 2 Megawatt Diesel Generator system with 3500 gallons of fuel, provides backup power for the facility. It is anticipated that cogeneration facilities will be installed in the next 6 to 12 months. UPS power is fed into redundant Power Distribution Units and from there into Remote Power Panels (RPP).
  .
 
> HVAC: Air conditioning and air handling services for the facility are provided by a series of three fully redundant 180-ton data center specific closed loop chiller systems. These systems provide over 500 tons of humidity and temperature controlled air conditioning to the data center.
The data center floor is fed by 20 and 30-ton individual, redundant Computer Room Air Conditioning (CRAC) units. The colo area is kept at 72 degrees and 45% humidity at all times. Critical airflows are monitored for hydrogen at all times, and temperature and humidity sensors are placed throughout our facility to provide early warning in the event of a system failure.
  .
 
> Security: The entire facility is alarmed and monitored with video cameras and off-site alarm monitoring services. Customers can access the building 7x24x365 via an intercom system and camera
connected to the manned video surveillance system. Once customer service personnel have visually identified the customers, they are allowed into the lobby area. This area becomes a mantrap as the door locks behind them. Once in the lobby/man trap, access is monitored by another video camera. The entire facility is alarmed and monitored with video cameras and off-site alarm monitoring services. Customers can access the building 7x24x365 via an intercom system and camera connected to the manned video surveillance system. Once customer service personnel have visually identified the customers, they are allowed into the lobby area.
This area becomes a mantrap as the door locks behind them. Once in the lobby/man trap, access is monitored by another video camera. The customers are then required to use the biometric hand scanners and a security code to gain access to the customer service area, which is manned 7x24x365. Customer Service Personnel must use another hand scanner and a code and proximity card to escort customers into the data center. All equipment entering and leaving the data center is checked for serial numbers and descriptions against the customers file in the computer system. Customers are then escorted back out of the building. This hands-on approach to security is much more effective than data centers that allow customers to come and go unsupervised.
  .
  > Monitoring: Manned 24 x 7 x 365, the Operation and Control Center (OCC) provides the facilities to monitor all Heating, Ventilation and Air Conditioning (HVAC), fire suppression systems and security systems onsite by specially trained personal.
 

 
The colo area is kept at 72 degrees and 45% humidity at all times. Critical airflows are monitored for hydrogen at all times, and temperature and humidity sensors are placed throughout our facility to provide early warning in the event of a system failure.

The data center floor is fed by 20 and 30-ton individual, redundant Computer Room Air Conditioning (CRAC) units.The data center floor is fed by 20 and 30-ton individual, redundant Computer Room Air Conditioning (CRAC) units. The data center floor is fed by 20 and 30-ton individual, redundant Computer Room Air Conditioning (CRAC) units.
  .
 
> Monitoring: In addition to our sophisticated monitoring systems, we have a team of expert engineers monitoring the data centres 24 hours a day, ensuring that any potential issues with the platform are prevented before they can even happen.
Data centers are staffed 24/7, both entrances and exits are electronically secured and continuously monitored via closed-circuit cameras. Data centers are only accessible to qualified network and data center technicians.

> Network Redundancy: The Level3 Communications Data Center uses intelligent end-user routing software from RouteScience between MCI, Level(3), Qwest, Verio, XO and WilTel. RouteScience identifies which path is the most efficient for each data packet and then routes the packet to its destination on the fastest path. This increases the speed at which web pages sent from our datacenter arrive at their destination. Most other datacenters use BGP to route packets.
  .
 

> Atlanta Data Center: The facility is the primary Internet interconnection point for the region and our building was designed from the ground up to be a facility for large-scale carriers and offers many amenities not available in other facilities. This allows us to offer services that other hosting companies do not have available.Our facility is a Type IV DC facility with at least N+1 redundancy on all components down to the rack level. Our engineering team has also performed two separate Level 5 commissioning tests, the highest available, to simulate and document 10 years of potential critical failures and recovery operations within the facility.

  .
 
> Power System: The building contains it’s own Baltimore Gas & Electric power substation connected to two separate Atlanta City 13,200v power grids each fed by its own set of two additional substations.

Our facility is fed directly by grid power at 13.2kv and transformed to 480v within our facility which is then filtered by a high capacity Transient Voltage Surge Suppression System (TVSS) filtering all grid power disturbances up to 1,000,000 Amps.
To ensure no downtime in the case of a power grid or transformer disruption, power is then distributed to two completely separate, purposefully non-paralleled, but Phase Synchronized, 300kW PowerWare UPS systems. Each is capable of maintaining 100% of our power load allowing for fully maintenance concurrency of all electrical gear with no down time. A separate Maintenance Bypass has been installed on each UPS.
.
| | | | | | |